Runco RS232 Przewodnik Instalacji Strona 11

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 64
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 10
Using the Operation Commands Table
RS232 Control 11
Note: Replies are always in ALL CAPS, regardless of how the query was sent.
op A1 ascii.response = numeric [CR] OPA11137=1
The tile received the
command and has set the
response type to numeric
and will reply with the
value number
op A1 pattern ? [CR] OPA11036=6
The current test pattern is
black.
op A1 ascii.response = data [CR] ACK
The tile received the
command and has set the
response type to data and
will reply with only a
number
op A1 pattern ? [CR] 6
The current test pattern is
black.
Command Sent Response Explanation
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 63 64

Komentarze do niniejszej Instrukcji

Brak uwag