clone.setting 1391 0-8
255
= <operation>
Applicable only to tile A1. Other
processors will NAK.
Force the settings from tile A1
onto all other tiles in the system.
Ta r g et s:
0: Clone only the operation given
in the data
1: Clone items on Backlight
Menu
2: Clone items on Miscellaneous
menu
3: Clone items on Input Setup
Menu
4: Clone items on Size & Position
menus
5: Clone items on Big Picture
Setup menu (except for row and
column)
6:Clone items on Color Balance
Menu
7: Clone items on Scaling Menu
8: Clone items on Factory Set-
tings Menu
255: All items from targets 1-8
30
color.temp 1268 = ? 3200K
5500K
6500K
8500K
NATIVE
CUSTOM
0
1
2
3
4
5
31
colorspace 1180 ?RGB
YPBPR
0
1
32
commands.received 1107 RS232
RS485
AUX232
0
1
2
? 0 – 32767
Used only to indicate that com-
mands have been received.
Resets to zero upon reaching its
maximum value.
33
contrast 16388 = ? + 0 – 255
Used when digital source is
YPbPr.
Operation Commands for Runco WindowWall
Row
Operation
or
String [ST]
Operation or
String
number
(Target)
Target or Target number
must be in parentheses.
(Target
number)
Command
types allowed
(Use only
one symbol)
Value
If numbers listed first, use
numbers only. Data in
[square brackets] is for
information only.
Value number
Notes