78
matrix.route.module 1384 A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
? bit field (see description)
Use only on tile A1. Other pro-
cessors will accept the com-
mand but the master needs to
have the information for all tiles.
So it must get the command first
and then pass it on to the rele-
vant tile.
Returns a bit field that represents
the current FPGA route settings
for the tile requested. To set
each switch individually, use
op_TOP_ROUTE
bit 0-1 = switch 1
bit 2-3 = switch 2
bit 4-5 = switch 3
bit 6-7 = switch 4
bit 8-10 = external loop
bit 11-12 = internal loop
bit 13 = 0 if the external loop is
enabled
Values for switch 1 & 2:
0= Digital 1
1=Digital 2
2=use loop
3=use loop
Values for switch 3 &4:
0= Digital 3
1=Digital 4
2=use loop
3=use loop
Values for external loop
0=digital 1
1=digital 2
2=digital 3
3=digital 4
4=Dual Link In
Values for internal loop
0=digital 1
1=digital 2
2=digital 3
3=digital 4
Operation Commands for Runco WindowWall
Row
Operation
or
String [ST]
Operation or
String
number
(Target)
Target or Target number
must be in parentheses.
(Target
number)
Command
types allowed
(Use only
one symbol)
Value
If numbers listed first, use
numbers only. Data in
[square brackets] is for
information only.
Value number
Notes